Hinged EI260-C fire doors for freezer rooms
Door System has developed a new single-leaf hinged EI260-C fire door for freezer rooms. The fire door is manufactured in Denmark and has been tested by the Danish Institute of Fire and Security Technology (DBI).
The door passed the critical time limits of 1 hour and then 1 hour and 8 minutes, giving it a more comprehensive range of applications.
Extra large size
The EI260-C fire door for freezer rooms was tested with a wall opening of 1460 x 2550 mm (clear opening 1220 x 2430 mm). Since the door lasted for more than 68 minutes, we will have the possibility to deliver the door in a size larger than the tested door and supply the door with more options. We will know when we receive the final test report from DBI.
Safety has been in focus
The new fire door has been developed with a brand-new heated exterior handle and interior pushbar, both of which provide a high level of safety for the door solution.
To prevent condensation, the fire door is fitted with heating wires on the door leaf and in the frame. Furthermore, the door has been tested with our standard freezer room seals, so the door provides optimal sealing and insulation.
The door is available in stainless steel and galvanised versions and can be supplied as a self-closing freezer room fire door. The door has elevating hinges, that lifts the door free of the floor.
Installation in heavy firewalls
The EI260-C fire door is approved for installation in a heavy fire wall with the option of using freezer room elements without the risk of thermal bridges. It has been also tested and approved to be placed at height.
Also approved installed in plaster board and panel wall
We have performed (and had approved) an additional test of our new freezer room fire door installed in plaster board and panel wall, and with a new frame solution for the panel wall.
As always, the new tests were carried out at DBI - The Danish Institute of Fire and Security Technology.
Contact us to learn more about the options with the new EI260-C fire door for freezer rooms. Feel free to use the form below.
Test of the freezer room fire door installed in plaster board and panel wall
We have performed (and had approved) an additional test of our new freezer room fire door installed in plaster board and panel wall, and with a new frame solution for the panel wall.
As always, the new tests were carried out at DBI - The Danish Institute of Fire and Security Technology.
Door System's new EI260-C fire door for freezer rooms, installed in a heavy fire wall, has been tested by the Danish Institute of Fire and Security Technology (DBI). The door passed the critical time limit of 1 hour and 8 minutes, giving it a more comprehensive range of applications.
Download
DoorSystem-datasheet-fire-doors-fire-sliding-doors-ENG.pdf80 KB
Data sheet for Door System fire doors and fire sliding doors
Certificate-2531-CPR-CDB10008-DoorSystem-fire-doors.pdf245 KB
Certificate for Door System fire doors approved in accordance with EN 16034
Classification-report-DoorSystem-fire-doors-extract.pdf86 KB
Extract from the classification report for Door System fire doors
DoorSystem-operations-maintenance-hinged-doors.pdf2 MB
Operations and maintenance manual for Door System automatic and manual hinged doors
DoorSystem-profile-brochure.pdf604 KB
Read more about Door System A/S